product Description
MGSGO Halogen-free power cables for marine craft , copper screened ,Marine Cables
| Structure & Specification | |
Type: | Low Voltage |
Rated voltage: | U0/U 0,6/1 kV |
Conductor Material: | Stranded copper conductors |
Stranding | Thin bare wire stranded conductor; VDE 0295, class, 5 |
Insulation Material: | Heat-resistant EPR |
Reinforcement | Polyester tape |
Jacket: | elastomer compound to olefin based copolymer |
Shield: | Foil wrapping + Bare copper braided screen |
Outer jacket color: | Black/Optional |
Bending radius: | 5x outer Ø |
Operating temperature range: | at conductor max. +85°C |
Certificate: | CE,RoSH, ISO9001 |
Standard | * acc. to VG 95218-60, with screen and natural insulation integrity in case of fire without a flame retardant barrier |
Properties | * halogen-free and flame retardant |
Application:
Halogen-free power cables for marine craft are used for fixed installation on ships in all rooms and open decks as control and power cables.


PVC insulated and sheathed five-core power cable
1.Scope of application
The product is suitable for power transmission in power lines with rated voltage 3.6/6KV and below. In order to meet the development and security needs of distribution system, five-core power cable separates the neutral line from the zero line of low-voltage distribution system engineering, so that the system operation is more stable and the safety of operators is ensured. Our company five core power cable obtained the national utility model patent, patent number: 9123089.4.
2. Model specifications
<1>the corresponding meaning of the letter.
V-PVC Insulation L-Aluminum Core T-Copper Core (omitted) V-PVC sheath
<2>Numbers correspond to meanings.
Previous: 2- tape armoring 3- fine steel wire armoring 4- thick steel wire armoring
Last bit: 2- PVC sheath
<3>See Table 1 for models.
Table 1

<4>See Table 2 for models.
Table2

3.Structure diagram

4.Technical parameters
<1>conductor DC resistance meets the requirements of GB/T3956-1997.
<2>The insulation performance of the finished cable meets the requirements of GB12706.1. It shall withstand the AC voltage test specified in Table 3 for 5 minutes without breakdown.

5.product features
<1>The identification sign of the insulation wire core adopts three kinds: insulation color extrusion; Monochrome, with 0, 1, 2, 3, 4 code identification; Double color, extruded color bar.
<2>Five-core power cable is suitable for three-phase five-wire transmission and distribution system. Because the neutral core and ground wire are separated, the system operation is more stable and the operator is more safe. The five-core cable adopts unique tile design, which makes the cable have the characteristics of stable structure, light weight and small outer diameter.
6. Conditions of use
<1>The maximum rated operating temperature of the conductor is 70℃;
<2>When short-circuit occurs (5S maximum duration), the maximum operating temperature of the conductor is 160℃;
<3>The ambient temperature of cable laying shall not be lower than 0℃;
Allowable bending diameter of cable laying: single core cable is not less than 40 times of the cable diameter;Multicore cable not less than 30 times of cable diameter.
Concentric conductor power cable
1. Scope of application
This product is suitable for power transmission lines with rated voltage up to and including 0.6/1KV.
2.product characteristics
<1>With low and uniform positive (inverse) sequence and zero sequence impedance, is conducive to improve the quality of power supply.
<2>The reactance value of the concentric layer conductor is much lower than that of the fourth core of the ordinary four-core cable in the zero-sequence working state, which is conducive to the sensitive action of the short-circuit automatic protection device, so as to ensure the safe operation of the cable related equipment.
<3>It has strong anti-electromagnetic interference performance and anti-lightning performance.
<4>Five-core power cable with the same conductor is suitable for three-phase five-wire distribution system.
3.Models and specifications
<1>Meaning of letters
-T: concentric conductor ZR: flame retardant NH: fire resistant (the rest are the same as ordinary power cables)
<2>See Table 1 for models.
Table 1

<3> See Table 2 for models.
Table 2

4.Structure diagram

5.Technical parameters
<1>conductor DC resistance
Power cables with plastic insulation and sheathed.
<2>See Table 3 for insulation resistance.
Table 3

<3>AC voltage test
The finished cable will not break down under AC voltage test of 50Hz, 5min and 3500V.
For single core cable, the immersion pressure test is carried out.
<4>AC resistance and impedance values are shown in Table 4.
Table 4

6. Conditions of use
<1>the conductor's maximum long-term permissible operating temperature: PVC insulation 70℃;
XLPE insulation 90℃.
<2>When the cable is short-circuit (5s maximum duration), the maximum conductor temperature shall not exceed:
PVC insulated cable 160℃;
XLPE insulated cable 250℃.
<3>The ambient temperature during laying shall not be lower than 0℃.
<4>The allowable bending diameter of the cable is not less than 40 times of the outer diameter of the single core cable;
Multicore cable not less than 30 times of cable diameter.
<5>Flame retardant and fire resistant cables meet corresponding flame retardant and fire resistant performance requirements respectively.
Metal-shielded power cable
1.Scope of application
The product is suitable for use in AC/DC power lines with rated voltage up to and including 0.6/1KV. In addition to the electrical characteristics of ordinary plastic cable, this product also has strong anti-electromagnetic interference, anti-lightning performance, equalizing potential and improving the quality of power supply. Especially suitable for places with precision electronic devices, such as computer center, aerospace control center, intelligent building.
2. Model specifications
<1>the corresponding meaning of the letter
-P: metal shielded power cable ZR: flame retardant NH: fire resistant (the rest are the same as ordinary power cables)
<2> See Table 1 for models.
Table 1

<3> See Table 2 for models.
Table 2

3.Structure diagram

1- Copper (Aluminum) Conductor 2-PVC (XLPE) Insulation 3- Claddle 4-PVC Inner sheath 5- Copper tape Shield 6-PVC External sheath
4.electrical performance
<1>conductor DC resistance meets the requirements of GB/T3956-1997.
<2>See Table 3 for insulation resistance.
<3>AC voltage test.
The finished cable does not break down when subjected to AC voltage test of 50Hz, 5min and 3500V. For single core cable, the immersion voltage test is carried out.
5. Conditions of use
<1> the conductor's maximum long-term permissible operating temperature: PVC insulation 70℃;
XLPE insulation 90℃.
<2> When the cable is short-circuit (5s maximum duration), the maximum conductor temperature shall not exceed:
PVC insulation 160℃;
XLPE insulation 250℃.
<3>The ambient temperature during laying shall not be lower than 0℃.
<4>The bending diameter of the cable is allowed to be the same as that of ordinary power cables.
0.6/1kV overhead insulated cables
1.Scope of application
The product is suitable for overhead power lines with rated voltage up to and including 0.6/1KV, and can be used for fixed laying or leading lines.
2.Model specifications
<1> the corresponding meaning of the letter
JK-Overhead cable L (T) -Aluminum core (copper core, generally omitted) Y-polyethylene insulation V-PVC insulation
<2>See Table 1 for models.
Table 1

<3>See Table 2 for models.
Table 2

3.Structure diagram

4. Conditions of use
<1> PVC, PE insulated cable conductor long-term permissible operating temperature of 70℃.
<2>The permissible operating temperature of conductor of XLPE insulated cable is 90℃ for a long time.
<3>The maximum allowable temperature of the cable in short circuit (5s maximum duration) :
PVC insulation for 160℃; Polyethylene insulation is 150℃; XLPE insulation is 250℃.
<4> the cable laying temperature is not lower than 0℃.
<5> Allowable bending radius of cable:
PVC, PE insulation allowed bending radius is not less than 6 times the cable diameter;
The allowable bending radius of XLPE insulation is not less than 15 times the cable diameter.
XLPE insulated overhead cables with steel - alumina strand core for rated voltage up to and including 10kV
1.Scope of application and characteristics
The product is suitable for overhead power lines with rated AC voltage up to and including 10kV. Due to its use of steel-aluminum strand core as a conductor, it has a certain bearing capacity, relative to the general overhead cable tensile strength is higher.
2.Model specifications
<1>the corresponding meaning of the letter
JK-Overhead Cable LG-Steel Aluminum Stranded Wire Core YJ-XLPE Insulated/Q-Light
<2>See Table 1 for models and use.
Table 1

<2>See Table 2 for models and use.
Table 2

3.Structure diagram
4.Performance parameters
<1>Conductor structure, DC resistance and tensile force meet the requirements of the above standards.
<2>The cable withstands the test voltage in Table 4 for 1min without breakdown.
Table 4

<3>insulation resistance: at room temperature, the cable soak in water for 1 h, 80 ~ 500 v dc voltage source, the stable time of 1 min ~ 5 min, rated voltage 10 kv insulation resistance of cable should be no less than 1500 M Ω / km, light thin insulation structure insulation resistance of cable should be no less than 1000 M Ω / km.
5.Conditions of use
<1> Rated voltage 1KV, 10KV.
<2>the cable laying temperature is not lower than 0℃.
<3>When short-circuit occurs (5S maximum duration), the maximum temperature of the cable is 250℃.
<4>the long term permissible operating temperature of the conductor is 90 ℃.
<5>the bending radius of the cable: 1KV overhead cable is not less than 6 times of the cable diameter;
10kV overhead cable is not less than 20 times of cable diameter.
10kV, 35kV overhead insulated cables
1.Scope of application
This product is a new series of products for the transmission of electric energy by overhead transmission lines. It is preferred for power grid construction and transformation of 10kV and 35kV transmission lines. It is the most suitable line maintenance and safety series products. Flexible copper wire core products are suitable for transformer down lead.
2.Model specifications
<1>the corresponding meaning of the letter
JK- aerial cable T-copper core (omitted) TR- soft copper core L-aluminum core LH- aluminum alloy core
Y- polyethylene insulation YJ- XLPE insulation /B- natural XLPE insulation Q- light XLPE thin insulation
<2>See Table 1 for models and laying precautions.
Table 1


3.Structure diagram

4. Technical parameters
<1>The tensile force of the bearing strand, the DC resistance of the conductor and the tensile force meet the requirements of GB14049.
<2>See Table 5 for other technical
table 5

5.Conditions of use
<1> Rated voltage is 10KV, 35KV.
<2>The cable laying temperature shall not be lower than 0℃.
<3>Maximum temperature of the cable in short circuit (5s maximum duration) :
XLPE insulation 250℃;
High density polyethylene insulation 150℃.
<4> The maximum permissible long-term operating temperature of the conductor:
Cables with load-line structure, determined by the maximum permissible long-term operating temperature of insulation.
XLPE insulation 90℃;
High density polyethylene insulation 75℃.
<5>Allowable bending radius of cable:
Single core cable not less than 20 times cable diameter;
Multicore cable not less than 15 times cable diameter.
Heat resistant silicone rubber insulated and sheathed power cables for frequency converter rated voltage 0.6/1kV
1.Scope of application
This product is suitable for high temperature - resistant grade inverter power transmission system.
2.Model name

3.Model and specification

4.the use of characteristics
●Max. permissible operating temperature of conductor for a long time is 180 ℃; The lowest working temperature can reach -60℃.
● Short-circuit temperature of the conductor shall not exceed 350℃ (5s maximum duration).
The laying temperature of the cable shall not be lower than 0℃.
● The bending radius of copper wire or tinned copper wire braided shielded cable laying shall not be more than 5 times of its outer diameter, and the bending radius of copper wire wound copper tape wrapped composite shielded cable laying shall not be more than 10 times of its outer diameter.
5.Product characteristics
● Can improve the power factor of the system, reduce the adverse influence of high harmonic on cables and equipment, reduce the noise of the motor.
Has a good shielding performance, the shielding layer transfer impedance measuring 30 MHZ, 60 MHZ two point value, respectively is not greater than 25 Ω / m, 50 Ω / m.
● The ideal shielding coefficient of the cable: copper wire braided shielding is not more than 0.9, copper wire wrapped copper tape wrapped composite shielding is not more than 0.6.
● Can improve the cable and system electricity safety performance.
The change rate before and after 200℃ aging test is not more than ±25%.
6.Schematic diagram of product structure

7.Length of delivery
● Delivery length shall not be less than 100m.
● Delivery in any length is subject to mutual agreement.
● Length measurement error is not more than ±0.5%.
Irradiated cross-linked overhead insulated cables with rated voltage of 10kV
1. Product use
This product is a new series of products for the transmission of electric energy by overhead transmission lines. It is preferred for the construction and transformation of 10kV transmission lines in power grid. It is the most suitable series of products for line maintenance and safety.
2.Model name
The product model meets the requirements in Table 1.
Table 1

3.Product Specifications
Product specifications shall conform to table 2
table 2

4.the use of characteristics
<1>The maximum permissible operating temperature of the conductor for a long time is 105℃.
<2>When short-circuit occurs (5S maximum duration), the maximum temperature of conductor shall not exceed 250℃
5.Product characteristics
<1>The conductor DC resistance of the finished cable shall meet the requirements of GB/T3953, GB/T3955, GB/T3956 and JB/T8134 respectively;
<2>The non-insulated shielded cable shall undergo the insulation resistance test specified in GB/T3048.6;
<3>The finished cable shall be subjected to AC voltage test and 4H AC voltage test as specified in GB/T3048.8;
<4>The cable shall undergo the bending performance test specified in GB/T2951.23;
<5>The cable shall be subjected to the impulse voltage test and AC voltage test specified in GB/T3048.8;
<6>no insulation shielded cable should be subjected to GB/T3048.7 insulation resistance to electric mark test;
<7>The cables without insulation and shielding shall undergo the weather resistance test specified in Appendix A of GB/T14049;
<8>The cable shall undergo GB/T14049 insulation adhesion (slip) test.
6.Length of delivery
<1> The delivery length of cables and the length and quantity of permitted short cables shall be agreed by the two main parties.
<2>length measurement error should not exceed ±0.5%.
Irradiated cross-linked polyolefin insulated halogen-free low smoke flame retardant power cable
1. Scope of application
It is mainly used for fire alarm with rated voltage 600/1000V and below, and for power supply lines of emergency facilities such as fire fighting equipment, communication equipment and emergency passage transportation, which require fire resistance. It is especially suitable for the power transmission system which can ensure emergency shutdown, containment isolation, emergency cooling of reactor core, heat removal of reactor and prevent radioactive material from discharging to the surrounding environment under seismic load outside the containment of nuclear power plant.
2.Product model and specification
<1>Product models are specified in Table 1.

2.Product specifications are shown in Table 2

3.product characteristics
<1>with good electrical and insulation performance;
<2>with good heat aging performance, long-term continuous working temperature according to the selection of different varieties of 90℃ and 105℃.
<3>large load capacity, overload protection performance is strong;
<4>with no halogen, low smoke, low toxicity and environmental protection characteristics;
<5>cable combustion light transmittance is small;
<6>excellent flame retardant performance, can pass the beam combustion test;
<7>It has good fire resistance.
4. Main technical performance
<1> The working temperature of the finished cable reaches 90℃ and 105℃.
<2> The finished cable meets the requirements of GB/T19216 fire resistance test;
<3>The non-delay combustion performance of the finished product has passed the B type bunching combustion test stipulated by GB/T18380.3;
<4> cold resistance up to -40℃;
<5>insulation resistance constants Ki acuity 3.67 M Ω. Km;
<6>conductor resistance to meet the requirements of GB/T3956 conductor;
<7>Test according to GB/T17650 and GB/T17651
Smoke density transmittance ≥60%;
PH 4.3 or higher
Conductivity 10 mu S/mm or less
<8>The finished cable shall be subjected to the power frequency voltage withstand test specified in the table:

5.the use of characteristics
<1>The long-term operating temperature of the conductor shall not exceed 90℃ or 105℃;
<2> Under the condition of accident operation (duration not more than 5 seconds), the highest temperature of the conductor shall not exceed 270℃, and the temperature of the cable shall not be less than 0℃;
<3>Allowable bending radius of cable: non-armored type should not be less than 6 times of cable diameter; Armour type should not be less than 12 times of cable diameter
<4>before and after the use of the cable can not be mechanical impact, sharp tool scratches and other damage affecting the performance of the cable.
6.Length of delivery
<1> Delivery length shall not be less than 100m.
<2>According to mutual agreement, delivery can be made in any length.
<3> length measurement error is not more than ±0.5%.
And marine battery cable


Name | Length(mm) | Length(mm) | Length(mm) | Length(mm) | Length(mm) | Length(mm) |
CHJPFP86/SC | 1*2*0.75 | 3*2*2.5 | 7*2*1.5 | 14*2*1 | 24*2*0.75 | 30*2*2.5 |
150V-250V | 1*2*1 | 4*2*0.75 | 7*2*2.5 | 14*2*1.5 | 24*2*1 | 33*2*0.75 |
1*2*1.5 | 4*2*1 | 10*2*0.75 | 14*2*2.5 | 24*2*1.5 | 33*2*1 | |
1*2*2.5 | 4*2*1.5 | 10*2*1 | 16*2*0.75 | 24*2*2.5 | 33*2*1.5 | |
2*2*0.75 | 4*2*2.5 | 10*2*1.5 | 16*2*1 | 27*2*0.75 | 33*2*2.5 | |
2*2*1 | 5*2*0.75 | 10*2*2.5 | 16*2*1.5 | 27*2*1 | 37*2*0.75 | |
2*2*1.5 | 5*2*1 | 12*2*0.75 | 16*2*2.5 | 27*2*1.5 | 37*2*1 | |
2*2*2.5 | 5*2*1.5 | 12*2*1 | 19*2*0.75 | 27*2*2.5 | 37*2*1.5 | |
3*2*0.75 | 5*2*2.5 | 12*2*1.5 | 19*2*1 | 30*2*0.75 | 37*2*2.5 | |
3*2*1 | 7*2*0.75 | 12*2*2.5 | 19*2*1.5 | 30*2*1 | ||
3*2*1.5 | 7*2*1 | 14*2*0.75 | 19*2*2.5 | 30*2*1.5 |

Hot Tags: marine cables ship bridge, China, suppliers, manufacturers, factory, price, for sale